Input | Input Voltage | AC220V or AC110V(to be specified when placing order) | |
AC frequency | 47—440HZ | ||
Cold Surge Current | ≤60A(AC220V Input) | ≤30A(AC110 Input) | |
Current Leakage | ≤0.7MA(AC220V Input) | ≤0.4MA(AC110V Input) | |
Output | Maximum Input Voltage | DC 35KV | |
Maximum Output Current | DC 23MA | ||
Efficiency | ≥90(full load) | ||
Mean Time Between Failure (MTBF) | ≥1000H | ||
Response Speed | ≤1ms(from the switch Signal is given to the output current up to
90% of the setting current) | ||
Control Interface | TTL level switch control; high or low effective level can be chosen
(details refer to the control terminal specification) | ||
Pressure-proof | Input-Output, Input-Shell: AC1500V 10MA 60S; Output negative is
connected with machine shell. | ||
Protection | can work in open-circuit condition for a short time(Require a good
protective earthing and avoid arc between the positive and the
machine shell) | ||
Environmental | Operating Temperature:-10~40℃Relative Humidity (RH):≤90 | ||
Cooling Way | Force-Air Cooling (FAC) | ||
Dimension | L×W×H=207*144*97(mm) | ||
See more products from this supplier.